wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 2491 lm, Rated power 20,90 W, Luminous Efficiency 119 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 14825 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2600
20,90
840
opal
< 28
white
DALI
mp LINE 45 WD 2600 840 O W DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 2600 lm, Rated power 20,90 W, Luminous Efficiency 124 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 15151 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
3874
30,80
830
opal
< 28
white
DALI
mp LINE 45 WD 3874 830 O W DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 3874 lm, Rated power 30,80 W, Luminous Efficiency 126 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23060 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
4044
30,80
840
opal
< 28
white
DALI
mp LINE 45 WD 4044 840 O W DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 4044 lm, Rated power 30,80 W, Luminous Efficiency 131 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23566 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2491
20,90
830
opal
< 28
silver
DALI
mp LINE 45 WD 2491 830 O S DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 2491 lm, Rated power 20,90 W, Luminous Efficiency 119 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 14825 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2600
20,90
840
opal
< 28
silver
DALI
mp LINE 45 WD 2600 840 O S DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 2600 lm, Rated power 20,90 W, Luminous Efficiency 124 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 15151 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
3874
30,80
830
opal
< 28
silver
DALI
mp LINE 45 WD 3874 830 O S DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 3874 lm, Rated power 30,80 W, Luminous Efficiency 126 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23060 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
4044
30,80
840
opal
< 28
silver
DALI
mp LINE 45 WD 4044 840 O S DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 4044 lm, Rated power 30,80 W, Luminous Efficiency 131 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23566 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2491
20,90
830
opal
< 28
black
DALI
mp LINE 45 WD 2491 830 O B DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 2491 lm, Rated power 20,90 W, Luminous Efficiency 119 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 14825 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2600
20,90
840
opal
< 28
black
DALI
mp LINE 45 WD 2600 840 O B DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 2600 lm, Rated power 20,90 W, Luminous Efficiency 124 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 15151 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
3874
30,80
830
opal
< 28
black
DALI
mp LINE 45 WD 3874 830 O B DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 3874 lm, Rated power 30,80 W, Luminous Efficiency 126 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23060 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
4044
30,80
840
opal
< 28
black
DALI
mp LINE 45 WD 4044 840 O B DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 4044 lm, Rated power 30,80 W, Luminous Efficiency 131 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23566 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2491
20,90
830
opal
< 28
colour on request
DALI
mp LINE 45 WD 2491 830 O X DA MO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 2491 lm, Rated power 20,90 W, Luminous Efficiency 119 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 14825 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
2600
20,90
840
opal
< 28
colour on request
DALI
mp LINE 45 WD 2600 840 O X DA MO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 2600 lm, Rated power 20,90 W, Luminous Efficiency 124 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 15151 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
3874
30,80
830
opal
< 28
colour on request
DALI
mp LINE 45 WD 3874 830 O X DA HO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, covering opal, 3000 K, CRI 80, Rated Luminous Flux 3874 lm, Rated power 30,80 W, Luminous Efficiency 126 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23060 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
65
4044
30,80
840
opal
< 28
colour on request
DALI
mp LINE 45 WD 4044 840 O X DA HO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, covering opal, 4000 K, CRI 80, Rated Luminous Flux 4044 lm, Rated power 30,80 W, Luminous Efficiency 131 lm/W, Mac Adams 3, UGR < 28, Luminance ≥65° 23566 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 65 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2701
20,90
830
opal-3d
< 25
white
DALI
mp LINE 45 WD 2701 830 O3D W DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 2701 lm, Rated power 20,90 W, Luminous Efficiency 129 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10054 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2820
20,90
840
opal-3d
< 25
white
DALI
mp LINE 45 WD 2820 840 O3D W DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 2820 lm, Rated power 20,90 W, Luminous Efficiency 135 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10275 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4202
30,80
830
opal-3d
< 25
white
DALI
mp LINE 45 WD 4202 830 O3D W DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 4202 lm, Rated power 30,80 W, Luminous Efficiency 136 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15642 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4386
30,80
840
opal-3d
< 25
white
DALI
mp LINE 45 WD 4386 840 O3D W DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9016, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 4386 lm, Rated power 30,80 W, Luminous Efficiency 142 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15983 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2701
20,90
830
opal-3d
< 25
silver
DALI
mp LINE 45 WD 2701 830 O3D S DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 2701 lm, Rated power 20,90 W, Luminous Efficiency 129 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10054 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2820
20,90
840
opal-3d
< 25
silver
DALI
mp LINE 45 WD 2820 840 O3D S DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 2820 lm, Rated power 20,90 W, Luminous Efficiency 135 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10275 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4202
30,80
830
opal-3d
< 25
silver
DALI
mp LINE 45 WD 4202 830 O3D S DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 4202 lm, Rated power 30,80 W, Luminous Efficiency 136 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15642 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4386
30,80
840
opal-3d
< 25
silver
DALI
mp LINE 45 WD 4386 840 O3D S DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9006, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 4386 lm, Rated power 30,80 W, Luminous Efficiency 142 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15983 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2701
20,90
830
opal-3d
< 25
black
DALI
mp LINE 45 WD 2701 830 O3D B DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 2701 lm, Rated power 20,90 W, Luminous Efficiency 129 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10054 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2820
20,90
840
opal-3d
< 25
black
DALI
mp LINE 45 WD 2820 840 O3D B DA MO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 2820 lm, Rated power 20,90 W, Luminous Efficiency 135 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10275 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4202
30,80
830
opal-3d
< 25
black
DALI
mp LINE 45 WD 4202 830 O3D B DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 4202 lm, Rated power 30,80 W, Luminous Efficiency 136 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15642 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4386
30,80
840
opal-3d
< 25
black
DALI
mp LINE 45 WD 4386 840 O3D B DA HO 1126
| | | |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, similar to RAL 9005, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 4386 lm, Rated power 30,80 W, Luminous Efficiency 142 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15983 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2701
20,90
830
opal-3d
< 25
colour on request
DALI
mp LINE 45 WD 2701 830 O3D X DA MO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 2701 lm, Rated power 20,90 W, Luminous Efficiency 129 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10054 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
2820
20,90
840
opal-3d
< 25
colour on request
DALI
mp LINE 45 WD 2820 840 O3D X DA MO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 2820 lm, Rated power 20,90 W, Luminous Efficiency 135 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 10275 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4202
30,80
830
opal-3d
< 25
colour on request
DALI
mp LINE 45 WD 4202 830 O3D X DA HO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, cover opal 3D, 3000 K, CRI 80, Rated Luminous Flux 4202 lm, Rated power 30,80 W, Luminous Efficiency 136 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15642 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
wall mounting luminaire
1126
45
85
4386
30,80
840
opal-3d
< 25
colour on request
DALI
mp LINE 45 WD 4386 840 O3D X DA HO 1126
| |
wall mounting luminaire, linear, Luminaire body Extruded aluminum with reduced CO₂ footprint, colour on request, powder coating, direct beam distribution, cover opal 3D, 4000 K, CRI 80, Rated Luminous Flux 4386 lm, Rated power 30,80 W, Luminous Efficiency 142 lm/W, Mac Adams 3, UGR < 25, Luminance ≥65° 15983 cd/m², average rated life L 80 50.000 h ( for ambient temperature 25°C), dimmable with integrated DALI control gear, electrical connection via 3 + 2-pole connection terminal up to 2.5mm², Mains voltage 220-240 V Net type 50/60 Hz, Glow wire strength 650°C, Protection class I, IP 20, Luminaire length 1126 mm, Luminaire width 45 mm, Height 85 mm, 2,1 kg, .
Weitere Produkte aus dieser Serie
mp LINE 45 WD
The system is supplied in pre-assembled modules (housing, light inserts, light-optical cover, accessories).
light optics
opal 3D = light-optical 3D diffuser opal (20 mm height of visible light optics), three-sided diffuse distribution, direct distribution